Adaptec 2010S - SCSI RAID Storage Controller Guia do Utilizador
Consulte online ou descarregue Guia do Utilizador para Controladores RAID Adaptec 2010S - SCSI RAID Storage Controller. Adaptec 2010S - SCSI RAID Storage Controller User`s guide [en] Manual do Utilizador
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128

Ficheiro PDF · ·
Resumo do Conteúdo
STORAGE MANAGEMENT SOFTWARE USER’S GUIDE A DAPTEC SCSI RAID 2010S/ 2015S
R Adaptec Storage Management Software User’s Guide Combined RAID SW-UG.book Page i Monday, September 9, 2002 1:25 PM
ii Copyright © 2002 Adaptec, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in…
iii Adaptec Software License Agreement PLEASE READ CAREFULLY: THE USE OF THIS SOFTWARE IS SUBJECT TO THE SOFTWARE LICENSE TERMS OF ADAPTEC, INC. AND…
iv 3. Ownership of Software. As Licensee, you own the media upon which the software is recorded or fixed, but Adaptec and its licensors retain title…
v b. if Adaptec or its distributor is unable to deliver replacement media which is free from defects in materials or workmanship, you may terminate…
vi Combined RAID SW-UG.book Page vi Monday, September 9, 2002 1:25 PM
vii Contents 1 Storage Management Software Overview 2 Storage Manager on ROM Overview 2-2 Keyboard Reference 2-3 Menu Control 2-3 Left Pane – Tree…
viii Adaptec Storage Management Software User’s Guide Formatting a Drive 2-29 Upgrading Firmware – Flash HBA Option 2-30 Creating a SMOR Boot Disk…
ix Command Statistics 3-47 Device I/O Statistics 3-47 Remote Communication 3-50 Connecting Across a Network 3-51 Installation and Configuration 3-51 4…
x Adaptec Storage Management Software User’s Guide BDMI Introduction B-1 System Requirements B-2 Adaptec CI B-3 Installing DMI Support B-4 Adaptec DMI…
Storage Management Software Overview Your Adaptec RAID controller includes the following software tools to manage your storage subsystem: Storage…
Storage Manager On ROM (SMOR)—A built-in utility that is part of the controller’s BIOS code. You can start SMOR by pressing Ctrl+A during BIOS…
In this Chapter Overview 2-2 Keyboard Reference 2-3 Menu Reference 2-4 Icon Reference 2-6 Screen Layout 2-6 Running SMOR 2-9 Information and…
Overview Storage Manager on ROM (SMOR) is a BIOS-based setup utility that enables you to configure your Adaptec RAID controller without loading an…
The array groups are accessible during the build process, with data protected; however RAID performance is at a reduced level until the build is…
Left Pane – Tree View Control Right Pane – Information View Control Menu Reference The SMOR Main Menu changes dynamically depending on what is…
File RAID Action Help Read System Config Rescan the system. Unsaved configuration changes are lost. Set System Config Save and enable configuration…
Icon Reference SMOR uses the following icons in the Tree View: Screen Layout The SMOR interface works like the Windows Explorer tree- structured…
The Menu Bar To open a specific menu, press Alt+highlighted letter of the menu name. After a menu is open, you can select a specific menu item by…
The Right Pane – Information View To the right of the component tree is the Information View pane. This area displays information related to the…
Running SMOR Start SMOR by pressing Ctrl+A when the RAID controller BIOS message appears on the screen during the boot sequence. SMOR starts by…
Information and Configuration Views When you highlight an item within the Tree View, the corresponding Information View is displayed. Controller BIOS…
Enable SCSI CD-ROM Boot When enabled, the BIOS attempts to detect a bootable CD-ROM that uses the El-Torito format. This setting is disabled by…
Information Tab To view or change the configuration of the controller, highlight the controller in the Tree View. Available tabs are Information and…
Note: Adaptec RAID controllers report a cache size 16 MB less than the total installed memory value because the controller uses 16 MB as processor…
Boot Enable This option enables you to modify the boot process for systems with multiple peripheral controllers in cases where the controller BIOS…
Note: As reported means that the field displays the value returned by the controller firmware. Bus Each peripheral bus on a controller is assigned a…
Device Information Tab Individual devices are listed in the Tree View under the controller to which they are connected, as shown in Figures 2-7.…
The status condition is one of the following for attached devices: The SCSI Capabilities section is a list of controller capabilities. A check mark…
Mostrar as 128 páginas
Array and Array Group Information The Information tab for any array may be viewed by highlighting that array, as shown in Figure 2-8. Figure 2-8 Array…
The Description section displays a general description of the highlighted array, as follows: The Status section displays the current status of the…
Setting the Configuration There are two configuration options on the File menu: Read System Config—Causes SMOR to rescan to detect any changes in…
2 When the RAID Type window appears, select the RAID level you want to use. The default stripe size is selected automatically; however you can select…
3 Select the devices you want to include in the array: a To add devices to the array, highlight the device and press the Spacebar. A check mark…
Creating a Multilevel RAID Creating a multilevel RAID (RAID 10 or 50) is similar to creating a normal RAID 1 or RAID 5 array group. To create a RAID10…
2 A warning message appears, as shown in Figure 2-12. Select Yes or No. The array configuration for the devices is not deleted until you select File >…
Rebuilding a Failed Array To replace a failed drive in an array that is not protected by an automatic hot spare, follow these steps: 1 Remove and…
Upgrading Firmware – Flash HBA Option The firmware on your controller is upgradable using the Flash HBA option, which appears on the Action menu when…
4 Select Action > Flash HBA. The Source File Browser window appears, as shown in Figure 2-13. Figure 2-13 Source File Browser Window 5 In the Source…
Creating a SMOR Boot Disk To create a SMOR boot disk, click Action > Make Boot Floppy or use the Adaptec RAID Installation CD. You may need a SMOR…
In this Chapter Introduction 3-2 Installing Storage Manager 3-4 Running Storage Manager 3-5 Views 3-6 Status Reporting 3-22 Information Windows 3-22…
Introduction Adaptec’s Storage Manager gives you complete control over your storage subsystem, enabling you to manage your storage locally or remotely…
System Requirements Adaptec Storage Manager software and device drivers require approximately 4 MB of disk space. The host system should have at least…
Installing Storage Manager The original installation of the software starts with the installation instructions covered in chapter 4 of the Adaptec…
. Figure 3-1 Storage Manager Setup Window Running Storage Manager You can run Storage Manager in one of the following ways: Locally—On the same…
Views This section describes the two primary configuration views, which are: Physical Configuration View Logical Configuration View (includes Logical…
Figures 3-2 shows a sample view of a Physical Configuration. Figure 3-2 Physical Configuration Window
Logical Configuration View On the right side of the Logical Configuration View Window, shown in Figure 3-3, are all the physical devices that are…
The tool bar at the top of the Logical Configuration View window contains the following buttons: Switch View Switches to the Logical Information View.…
Logical Device Addresses Every device and array is assigned a logical device address by Storage Manager. This is the address used by the host…
The complete logical device address is composed of the following fields: Array groups are automatically assigned an address that corresponds to the…
Array Groups The tool bar at the top of the Logical Configuration View window, shown in Figure 3-4, contains the following buttons: You can use the…
To view the Array Group Information window, shown in Figure 3-5, double-click the appropriate array icon in the Logical Configuration View window.…
Note: The availability of the various buttons depends on the current configuration and state of the array. The toolbar at the bottom of the Array…
1 Select the Create Array Group button. The Select Array Type window appears, as shown in Figure 3-6. Figure 3-6 Select Array Type Window 2 Select the…
Click the drive icons you want to remove and then click Remove Drive. During the drive selection process some drives might be displayed in a blue…
you are prompted to select the direction of the copy as shown in Figure 3-7. Figure 3-7 Mirroring Drives in an Array If you want to monitor the…
Expanding and Extending Arrays – Windows XP, Windows 2000 and Windows NT only The following definitions are used in this section: Array…
Requirements and Restrictions Array expansion has the following system requirements and restrictions. Windows XP, Windows 2000, Windows NT 4.0, Server…
Note: If the drives are not in hot-pluggable carriers, power down the system before adding drives to the peripheral bus. 2 Start Storage Manager and…
Note: If a drive fails during expansion, the expansion may complete successfully. However, the new, larger array remains in a degraded state until the…
An array is not physically deleted until you exit Storage Manager and choose to save changes or select File > Set System Configuration. Status…
Double-click a controller or device icon to display an Information window for that controller or device. Host Bus Adapter Information Window This…
The following buttons are available: Configure Host Bus Adapter Window Click Configure in the Host Bus Adapter Info window to modify hardware…
The following buttons are available: Controller Caching – Windows NT only To ensure optimum performance, follow these steps: 1 Click Caching in the…
The Advisory setting allows the controller to use its own algorithms for cache management. This is more efficient than allowing the operating system…
The current controller model, firmware version, and firmware type are displayed. To specify an image file for the flash operation, you can type a path…
Device Information Window The Device Information Window is shown in Figure 3-11. Figure 3-11 SCSI Device Information Window
The Device Information window displays the following information: RAID drives display the name and level of the array to which they belong and the…
Device Configuration Window Click Configure in either Device Information or Array Group Information window to display the Device Configuration window…
Saving the Subsystem Configuration The Storage Manager File menu has the following options: Note: If you reset the NVRAM on the controller, any…
Events are generated for detected fault conditions as well as RAID status changes, and are described as follows: Event Log When events occur, they are…
When the Event Log button is selected, the Event Logs window appears, as shown in Figure 3-13. Figure 3-13 Event Logs Window The Event Logs window…
Note: Only the event messages that appear on the screen when you click Print are printed. Therefore, if you want to print specific messages, scroll…
You can select or modify the following parameters: Broadcasters are available on the following operating systems: Windows XP, Windows 2000 and Windows…
Windows XP, Windows 2000 & Windows NT The broadcaster collects events from the controller and records them to files in the c:\program…
This window displays a list of the events submitted to the application log by the broadcaster, as well as other applications. Adaptec events are…
Installing the Broadcaster When you install the controller driver, you automatically install the the broadcaster in /usr/dpt. During broadcaster…
2 Establish a permanent connection to an Internet Service Provider (ISP) or create a dial-up networking connection to your ISP. 3 Configure your email…
Formatting Drives Your controller can perform a low-level format on attached hard drives in standard 512-byte format. This function is available from…
Drive Failures Drive failures are indicated by flags, which differ depending on whether they refer to an array or a drive in an array. Failure…
Rebuilding a Degraded Array When a drive in an array fails, and that drive is not protected by an automatic hot spare, the array can be restored to…
You should reboot your operating system to ensure that the hot spare drive is recognized correctly. Hot spares are reserved to automatically replace…
Note: Data inconsistencies should not occur under normal conditions. However, a power failure that interrupts an array write operation can cause…
Select Options > Background Task Priority to control the relative priority of I/O from the operating system and background tasks. Figure 3-15 shows…
To see the HBA statistics window, shown in Figure 3-16, click I/O Stats in the Host Bus Adapter Info Window. Figure 3-16 HBA Statistics Window Cache…
Command Statistics Device I/O Statistics The total number of sectors written to disk by the controller is described by the formula: Write – Backs +…
I/O statistics are displayed in the Hard Drive I/O Statistics window, as shown in Figure 3-17. Figure 3-17 Hard Drive I/O Statistics Window The Hard…
Environments with a large number of sequential reads should generate a high number of Read-Ahead Hits relative to Total Sectors. These hits reduce the…
Remote Communication The Storage Manager Remote Communication feature enables you to use Storage Manager running on your local workstation to manage…
Connecting Across a Network Storage Manager can run as a client/server application across a network using a TCP/IP connection. The Storage Manager…
You must configure remote communication before it can be used. For both workstations and servers, this is done by editing the Storage Manager…
The following list shows all supported options. The value listed is the default; optional values are in parentheses. Setting up the Server If you are…
Linux The Linux communication server is installed during the Storage Manager software install process. The server module is copied to /usr/dpt and…
Connecting to Remote Systems Select Communication > Make Connection to use Storage Manager to manage the controller in a remote server system using…
Making a Manual Connection In the Manual Connections section of the Available Connections window, there is one icon for each protocol that you…
Using the Phonebook You can save the server name, address, user name, and protocol of systems you frequently access in the Phonebook, shown in Figure…
Using a Custom Connection Under the Custom Connections section of the Available Connections window, there is one icon for each system that you marked…
RAIDUTIL Command Line Utility In this Chapter Introduction The command line utility (RAIDUTIL) performs operations as soon as it has enough…
Exit Status RAIDUTIL exits with either of the following error status indications: Device Address Syntax When you use RAIDUTIL to specify a device or…
RAIDUTIL Command Line Utility Command Line Switches Following is a list of the switches available in RAIDUTIL for testing and controlling various…
followed by a drive address as discussed in Device Address Syntax on page 4-2. Multiple drive addresses on a command line must always be separated by…
RAIDUTIL Command Line Utility -D Delete logical drives This command deletes the specified drives and returns their capacity to unassigned space. If…
-z Specify logical drive stripe size Specifies the stripe size (in KB) for new RAID 0 and RAID 5 logical drives. Valid stripe sizes are: 8, 16, 32…
RAIDUTIL Command Line Utility RAID Operation -C Load/save configuration This switch has two options: A file name must follow the load or save…
Controller-Specific -a Action (task) control This switch has the following options which allow you to control tasks on the controller: Specify drives…
RAIDUTIL Command Line Utility Hot Spare Control -h Create hot spare drive This switch creates one or more stand-alone hot spare drives. The drives…
General Information and Feedback -? Display utility usage information This option displays a summary of the command usage information. This includes…
RAIDUTIL Command Line Utility -I Display inquiry information This switch displays controller specific information, including firmware revision, BIOS…
-P Pagination output Limits output to 22 lines, then prompts to press Enter to continue. Pressing Enter prints another 22 lines. Use this switch to…
SNMP Introduction SNMP (Simple Network Management Protocol) is a group of network management specifications that includes the protocol itself, the…
SNMP SNMP is widely used and supported on a variety of servers, workstations, bridges, routers, and hubs. SNMP support also includes other computer…
SNMP Management Console The SNMP management console is usually a client workstation running SNMP-based management software. The console software can…
Adaptec Controller group is a list of all Adaptec controllers in the system. This group contains the following information for each Controller…
SNMP Device Inquiry data Device capacity and block size Device RAID level and status (Optimal, Failed, etc.) Adaptec Array group contains all the…
What’s Included The Adaptec SNMP software components are included on the Adaptec RAID Installation CD. Specific components vary by operating system.…
SNMP Installing Adaptec SNMP Support The following topics describe how to install Adaptec SNMP software and SNMP support for Windows. Note: Ensure…
SNMP Architecture Figure shows the relationship of the SNMP to the other elements in a system that includes a RAID controller. Figure A-1. SNMP…
SNMP Adaptec SNMP Subagent The Adaptec SNMP subagent attaches to the operating system- specific master agent to handle SNMP requests for objects…
A-10 Adaptec Storage Management Software User’s Guide Combined RAID SW-UG.book Page 10 Monday, September 9, 2002 1:25 PM
B-1 B DMI In this Chapter Introduction The Desktop Management Interface (DMI) is a standard developed by the Desktop Management Task Force (DMTF) to…
B-2 Adaptec Storage Management Software User’s Guide DMI consists of three components: SP (Service Provider)—Manages the communication between the MA…
B-3 DMI Adaptec CI At startup time the CI gathers information about Adaptec RAID controllers and stores this information in a DMI format table. When…
B-4 Adaptec Storage Management Software User’s Guide Installing DMI Support Adaptec supplies the CI only. The SP and MI must be provided by the…
B-5 DMI The following is a list of groups contained in the Adaptec Mass Storage MIF file. For the attributes of each group, refer to the admpdmi.mif…
B-6
Adaptec, Inc. 691 South Milpitas Boulevard Milpitas, CA 95035 ©2002 Adaptec, Inc. All rights reserved. Adaptec, and the Adaptec logo are trademarks of…
Mais documentos para Controladores RAID Adaptec 2010S - SCSI RAID Storage Controller
Perguntas sobre Adaptec 2010S - SCSI RAID Storage Controller
Ainda não há perguntas sobre este manual. Faça a primeira.
Manuais e produtos relacionados com Controladores RAID Adaptec 2010S - SCSI RAID Storage Controller
- Controladores RAID Adaptec 2930U2 - Storage Controller Ultra2 SCSI 80 MBps Especificações

(190 páginas) - Controladores RAID Adaptec ASR-2120S Guia do Utilizador
(128 páginas) - Controladores RAID Adaptec 2010S - SCSI RAID Storage Controller Guia de Instalação
(54 páginas) - Controladores RAID Adaptec 6805Q Manual do Utilizador
(2 páginas)