Adaptec RAID 2810SA Guia do Utilizador Página 134

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 153
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 133
C-34
Command Line Interface (CLI)
enclosure prepare slot {enclosure} {slot}
Prepares a device in a slot for insertion/removal.
Parameters
{enclosure}
—ID associated with the enclosure management
device on which to prepare a slot.
{slot}
—Unit number associated with the slot.
enclosure set alarm [/on={
boolean
}] {enclosure}
Turns the audible alarm on or off.
Parameters
{enclosure}
—ID associated with the enclosure management
device whose audible alarm to set.
Switches
/on
—Specifies whether to turn the audible alarm on or off.
enclosure set fan [/off={
boolean
}] {enclosure} {fan} [{speed}]
Sets the speed of a specific fan.
Parameters
{enclosure}
—ID associated with the enclosure management
device on which to set the speed of a fan.
{fan}
—Unit number associated with the fan.
{speed}
—Speed at which to set the fan.
Switches
/off
—Specifies whether to turn off the fan.
enclosure set interval {second}
Sets the monitor reporting interval (in seconds).
Parameters
{second}
—Number of seconds for the monitor reporting
interval.