3-46
Storage Manager
Rebuilding a Degraded Array
When a drive in an array fails, and that drive is not protected by an
automatic hot spare, the array can be restored to Optimal status.
Note: You can select Rebuild even if the failed drive has not
been replaced and try using the drive again. If the rebuild
attempt is not successful, replace the drive before starting
another rebuild.
To rebuild an array, follow these steps:
1 Replace the failed drive according to the procedure in your
hardware documentation.
2 After the failed drive has been replaced, select
Logical Configuration View in Storage Manager.
3 Double-click the array group icon to open the Array Group
Information window.
4 Click Rebuild in the Array Group Information window to start
the rebuild process.
The drive displays a white flag to indicate that a rebuild operation is
in process. The array and LSU icons display yellow flags. The
percentage completion of the rebuild operation is displayed in the
Array Group Information window. When the rebuild is successfully
completed, the flags disappear and the array status returns to
Optimal.
Note: SCSI only—In a RAIDstation storage cabinet, drives
have hot swap (SCA-2) connectors so that failed drives can
be removed or replaced without software intervention. The
RAIDstation subsystem detects that a failed drive has been
physically replaced and the controller automatically starts a
rebuild operation.
Comentários a estes Manuais