9-17
enclosure Commands
enclosure set interval
To set the monitor reporting interval for a specific SAF-TE
enclosure management device, use the enclosure set
interval command. The monitor reporting interval indicates
how often the controller checks the status of the enclosure
management device and its associated components. In setting this
value, consider the needs of your computing environment. Setting
the monitor reporting level to less than ten seconds could cause
slower system performance.
Syntax
enclosure set interval {second}
Parameters
{second}
Specifies the number of seconds for the monitor reporting
interval. You can specify 1 to n seconds where n represents
the number of seconds for the monitor reporting interval.
(The maximum value is 86,400, the number of seconds in a
day.)
The default is 10 seconds.
Examples
Before setting the monitor reporting interval, you might want to
use the enclosure show status command to determine the
current monitor reporting interval setting.
As the following example shows, the current monitor reporting
interval setting is 10:
AAC0>enclosure show status
Enclosure UpTime D:H:M PowerCycle Interval Door Alarm
--------- -------------- ---------- -------- -------- -------
0 0:00:00 0 10 UNLOCKED OFF
.
.
.
Enclosure UpTime D:H:M PowerCycle Interval Door Alarm
--------- -------------- ---------- -------- -------- -------
1 0:00:00 0 10 UNLOCKED OFF