Adaptec 2120S - SCSI RAID Controller Guia do Utilizador Página 164

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 354
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 163
5-116
Adaptec SCSI RAID Software Reference Guide
container show failover
To display a list of failover disks assigned to an array, use the
container show failover
command. You assign failover disks
to an array with the
container set failover command.
Syntax
container show failover [{container}]
Parameters
{container}
Specifies the ID number (0 to 63) of the array whose assigned
failover disk(s) you want to display. If you do not specify this
parameter, the command displays all arrays and their assigned
failover disk(s).
Examples
The following example shows the failover disks assigned to array 0:
AAC0>container show failover 0
Executing: container show failover 0
container Scsi C:ID:L
--------- ----------------------------------
0 0:03:0 0:04:0
The example shows that array 0 was assigned disks 0:03:0 and 0:04:0
as failover disks.
Related Information
container commands:
container remove failover (page 5-86)
container set failover (page 5-101)
Vista de página 163
1 2 ... 159 160 161 162 163 164 165 166 167 168 169 ... 353 354

Comentários a estes Manuais

Sem comentários