11-42
Adaptec SCSI RAID Software Reference Guide
As the example shows, the temperature sensor status display
contains the following columns:
■ Enclosure
■ Sensor
■ Temperature
■ Threshold
■ Status
The following sections describe the information that the enclosure
show temperature command can display in these columns.
The Enclosure Column
The Enclosure column displays the ID associated with the enclosure
management device that you specified on the command line. If you
did not specify an ID, the enclosure show temperature
command displays the IDs for all enclosure management devices
connected to the controller. In the example, 0 is specified.
The Sensor Column
The Sensor column displays the unit number associated with the
temperature sensor that you specified on the command line. If you
did not specify a unit number, the enclosure show
temperature command displays the unit numbers for all
temperature sensors on the enclosure management device or
devices.
The Temperature Column
The Temperature column displays the internal enclosure
temperature for this temperature sensor, in degrees Fahrenheit. The
temperature can range from -10 degrees to 245 degrees Fahrenheit.
In the example, the temperature is 70 degrees Fahrenheit.
The Threshold Column
The Threshold column displays the temperature at which an alarm
will be sounded if the temperature goes above the threshold. In the
example, the temperature threshold is 120 degrees Fahrenheit. You
can change the temperature threshold by using the enclosure
set temperature command.