disk Commands
disk verify
To verify all blocks on a SCSI disk device and, optionally, repair any
bad blocks, use the disk verify command.
Syntax
disk verify [/repair{=boolean}] [/wait{=boolean}]
{scsi_device}
Parameters
{scsi_device}
Specifies the ID for the SCSI disk device that you want to
verify. A SCSI ID consists of a SCSI channel number (for
example, 0, 1, 2, 3, etc.), a SCSI device ID (0 through 15
inclusive), and a SCSI logical unit number (0 through 7
inclusive). See the scsi_device section on page 3-7 for more
information on how to specify the SCSI device.
Switches
/repair{=boolean}
Specifies whether to automatically repair bad blocks. If you set
this switch to TRUE, the command attempts to repair any bad
blocks. If you do not specify the switch, the command only
reports failures.
This switch defaults to FALSE.
/wait{=boolean}
Specifies whether to perform verification synchronously or
asynchronously. If you set this switch to TRUE, the command
performs the block verification synchronously and the
command prompt does not return until the block verification
operation completes.
The default is FALSE; that is, the command performs the
block verification asynchronously and the command prompt
returns immediately.