Chapter 2 Hardware Installation and Removal 17
▼ To Verify the Current Devices
1. Enter the Open Boot Prompt (OBP) and use the show-disks command to list
the current devices.
Note – Device paths might vary from this example, depending on the SPARC
system you are using and into which PCI-E slot the card is plugged.
2. Take note of the devices.
This will help you determine which device is the HBA after you install the HBA.
Installing the HBA
Note – For the Sun SPARC Enterprise T5120, T5220, T5140, and T5240 servers,
contact Sun support to install the HBA.
▼ To Install the HBA
1. Remove the safety clip from each internal SAS connector by using your thumb
and forefinger to gently press the tabs of the safety clip and pull the clip out.
See
FIGURE 2-5.
{0} ok show-disks
a) /pci@0/pci@0/pci@2/scsi@0/disk
b) /pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2/storage@2/disk
q) NO SELECTION
Enter Selection, q to quit: q
{0} ok