Chapter 8 Known Issues 55
The System Freezes When a Sun Storage 32GB
SLC SATA Solid State Drive (SSD) is Configured
In the HBA
CR 6806467
Issue: This occurs because the HBA has firmware prior to version 16732 installed on
it and the Sun Storage 32GB SLC SATA SSD has firmware version 8626 or earlier
installed on it.
Workaround: Do the following:
1. Upgrade the HBA to firmware version 16732, at minimum.
You can obtain the latest HBA firmware at:
http://support.intel.com/support/go/sunraid.htm
2. Power cycle the HBA host system.
3. Upgrade the SSD to firmware version 8850, at minimum.
You can obtain the latest SSD firmware at: http://www.sunsolve.sun.com
4. Power cycle the SSD.
Cannot Access the HBA From the GUI Nor Access
a LUN From the Host
CR 6820225
Workaround: Reboot the host system on which the HBA resides.
Data Miscompare With 3.5" SAS Disks
CR 6822080
Issue: After repeatedly scanning a Seagate SAS Cheetah 15K disk, inconsistent data
is reported, even though nothing has changed on the disk. This is due to an old
firmware version (prior to 0A1C) on the Seagate SAS Cheetah 15K disk, model
ST3450856SS (Sun part number: 390-0424-03).
Workaround: Upgrade the firmware on the Seagate SAS Cheetah 15K disk to version
0A1C, at minimum.
Comentários a estes Manuais