Adaptec SAS RAID Controllers Guia de Instalação Página 37

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 36
Chapter 2 Hardware Installation and Removal 23
Note At this point, there are no volumes created and the output from a probe-
scsi-all command will not display any drives.
If no errors or issues are discovered, continue to “Next Steps” on page 25 to
complete the installation process. If any issues are discovered, correct them and
retest the HBA before continuing.
To Test the HBA Installation on an x64 System
1. Power-up the computer and storage systems:
a. Ensure that all hard disk drives are securely installed.
b. Connect all power cords securely and plug them into the proper power
source(s).
c. If applicable, power on the disk drive enclosure.
If the enclosure provides HDD status indicators, make sure they are normal.
d. Power-on the computer system.
If the system provides HDD status indicators, make sure they are normal.
2. Enter the BIOS RAID Configuration Utility:
a. During POST, press Ctrl + A when prompted.
b. As the computer continues its startup sequence, review the boot messages to
determine the firmware version on the HBA.
Boot messages, similar to those shown in the following example, are displayed
that indicate the firmware version (in this example, the FW build is 15815).
Adaptec RAID BIOS V5.3-0 [Build 15815]
(c) 1998-2008 Adaptec, Inc. All Rights Reserved
<<<Press <Ctrl><A> for Adaptec RAID
Adaptec RAID Configuration Utility will be invoked after initialization.
Booting the Controller Kernel....Controller started
Controller #00: Sun STK RAID INT at PCI Slot:02, Bus:04, Dev:00, Func:00
Waiting for Controller to Start....Controller started
Controller monitor V5.3-0[
15815], Controller kernel V5.3-0[15815]
Battery Backup Unit Present
Controller POST operation successful
Controller Memory Size: 256 MB